Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Respir Care ; 69(4): 395-406, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38538026

RESUMO

BACKGROUND: Aerosol barrier enclosure systems have been designed to prevent airborne contamination, but their safety has been questioned. A vacuum tent was designed with active continuous suctioning to minimize risks of aerosol dispersion. We tested its efficacy, risk of rebreathing, and usability on a bench, in healthy volunteers, and in an ergonomic clinical assessment study. METHODS: First, a manikin with airway connected to a breathing simulator was placed inside the vacuum tent to generate active breathing, cough, and CO2 production; high-flow nasal cannula (HFNC) was applied in the manikin's nares. Negative pressure was applied in the vacuum tent's apex port using wall suction. Fluorescent microparticles were aerosolized in the vacuum tent for qualitative assessment. To quantify particles inside and around vacuum tent (aerosol retention), an airtight aerosol chamber with aerosolized latex microparticles was used. The vacuum tent was tested on healthy volunteers breathing with and without HFNC. Last, its usability was assessed in 5 subjects by 5 different anesthesiologists for delivery of full anesthesia, including intubation and extubation. RESULTS: The vacuum tent was adjusted until no leak was visualized using fluorescent particles. The efficacy in retaining microparticles was confirmed quantitatively. CO2 accumulation inside the vacuum tent showed an inverse correlation with the suction flow in all conditions (normal breathing and HFNC 30 or 60 L/min) in bench and healthy volunteers. Particle removal efficacy and safe breathing conditions (CO2, temperature) were reached when suctioning was at least 60 L/min or 20 L/min > HFNC flow. Five subjects were successfully intubated and anesthetized without ergonomic difficulties and with minimal interference with workflow and an excellent overall assessment by the anesthesiologists. CONCLUSIONS: The vacuum tent effectively minimized aerosol dispersion. Its continuous suction system set at a high suction flow was crucial to avoid the spread of aerosol particles and CO2 rebreathing.


Assuntos
Dióxido de Carbono , Aerossóis e Gotículas Respiratórios , Humanos , Vácuo , Respiração , Nebulizadores e Vaporizadores , Aerossóis
2.
PLoS One ; 17(3): e0264090, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35316263

RESUMO

The objective of this study was to characterize commercially-available cotton fabrics to determine their suitability as materials for construction of cloth masks for personal and public use to reduce infectious disease spread. The study focused on cottons because of their widespread availability, moderate performance and they are recommended for inclusion in home-made masks by international health authorities. Fifty-two cottons were analyzed by electron microscopy to determine fabric characteristics and fabric weights. Sixteen fabrics were selected to test for breathability and to construct 2-ply cotton masks of a standard design to use in quantitative fit testing on a human participant. Cotton mask fitted filtration efficiencies (FFEs) for 0.02-1 µm ambient and aerosolized sodium chloride particles ranged from 40 to 66% compared with the mean medical mask FFE of 55±2%. Pressure differentials across 2-ply materials ranged from 0.57 to > 12 mm H2O/cm2 on samples of equal surface area with 6 of 16 materials exceeding the recommended medical mask limit. Models were calibrated to predict 2-ply cotton mask FFEs and differential pressures for each fabric based on pore characteristics and fabric weight. Models indicated cotton fabrics from 6 of 9 consumer categories can produce cloth masks with adequate breathability and FFEs equivalent to a medical mask: T-shirt, fashion fabric, mass-market quilting cotton, home décor fabric, bed sheets and high-quality quilting cotton. Masks from one cloth mask and the medical mask were re-tested with a mask fitter to distinguish filtration from leakage. The fabric and medical masks had 3.7% and 41.8% leakage, respectively. These results indicate a well fitted 2-ply cotton mask with overhead ties can perform similarly to a disposable 3-ply medical mask on ear loops due primarily to the superior fit of the cloth mask which compensates for its lower material filtration efficiency.


Assuntos
COVID-19 , Filtração , Gossypium , Humanos , Têxteis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA